R-392 Stage Gain Chart

STAGE GAIN CHARTS

Ref: Para 104, R-392 Manual

Connect VTVM or DVM between the diode load (red test jack J615) and ground.
Connect signal generator output to antenna (via 50 micro-micro farad cap) or
to internal points (via .05 microfarad cap); ensure sig gen ground is also connected
to receiver ground. Table signal generator voltages are the minimum and maximum
sig gen output required to generate -2.5 volts across the diode load.

RF Subchassis Stages.
---------------------------------------------------------------------------------------
Signal generator connection point Frequency (MC) Sig Gen output (microvolts)
---------------------------------------------------------------------------------------
ANT binding post, E101 0.5 to 32 1 to 4
Test Point E201 (grid of V201) 0.5 to 32 3 to 7
Test Point E202 (grid of V202) 0.5 to 32 3 to 7
Test Point E203 (grid of V203) 0.5 to 8 25 to 45
Test Point E204 (grid of V204) 8 to 32 20 to 35
Test Point J808 (grid of V801) 3 to 2 40 to 70
---------------------------------------------------------------------------------------

IF Subchassis Stages. (Generator set to 455 KHz)
---------------------------------------------------------------------------------------
Sig Gen Sig Gen output (microvolts)
Connection Point 2 KC BW 4 KC BW 8 KC BW
--------------------------------------------------------------------
Grid of V501 130-180
Grid of V502 3300-6000 3200-5900 2900-5700
Grid of V503 24000-41000 28000-45000 22000-38000
Grid of V504 25000-40000 25000-40000 23000-37000
Grid of V505 22000-34000 22000-32000 25000-35000
Grid of V506 50000-70000 50000-70000 50000-70000
--------------------------------------------------------------------